voltar
Disciplina:
INOVAÇÕES TÉCNICAS NAS TERAPIAS DAS ENFERMIDADES MÚSCULO-ESQUELÉTICA
CRÉDITOS: 4
CARGA HORÁRIA: 60h
DOCENTE: André Luis Selmi
Ementa
Análise e discussão crítica das mais recentes técnicas envolvendo o diagnóstico, tratamento, reabilitação e prevenção das lesões e doenças músculo-esqueléticas, incluindo aspectos anatômicos e fisiopatológicos.
Bibliografia
- FITZPATRICK N, LEWIS D, CROSS A. A biomechanical comparison of external skeletal fixation and plating for the stabilization of ilial osteotomies in dogs. Vet Comp Orthop Traumatol. 2008;21(4):349-57.
- GOH CS, SANTONI BG, PUTTLITZ CM, PALMER RH. Comparison of the mechanical behaviors of semicontoured, locking plate-rod fixation and anatomically contoured, conventional plate-rod fixation applied to experimentally induced gap fractures in canine femora. Am J Vet Res. 2009 Jan;70(1):23-9.
- GORMAN SC, KRAUS KH, KEATING JH, TIDWELL AS, RAND WM, PARKINGTON JD, BOUDRIEAU RJ. In vivo axial dynamization of canine tibial fractures using the Securos external skeletal fixation system. Vet Comp Orthop Traumatol. 2005;18(4):199-207.
- JOHNSON AL, SCHAEFFER DJ. Evolution of the treatment of canine radial and tibial fractures with external fixators. Vet Comp Orthop Traumatol. 2008;21(3):256-61.
- KIRKBY KA, LEWIS DD, LAFUENTE MP, RADASCH RM, FITZPATRICK N, FARESE JP, WHEELER JL, HERNANDEZ JA. Management of humeral and femoral fractures in dogs and cats with linear-circular hybrid external skeletal fixators. J Am Anim Hosp Assoc. 2008 Jul-Aug;44(4):180-97.
- REEMS MR, BEALE BS, HULSE DA. Use of a plate-rod construct and principles of biological osteosynthesis for repair of diaphyseal fractures in dogs and cats: 47 cases (1994-2001). J Am Vet Med Assoc. 2003 Aug 1;223(3):330-5.
- RISSELADA M, VERLEYEN P, VAN BREE H, VERHOEVEN G. The use of an external skeletal traction device for distal fractures in the dog. A clinical case series of 11 patients. Vet Comp Orthop Traumatol. 2007;20(2):131-5.
- SCHWARTZ Z, GRIFFON D. Nonrigid external fixation of the elbow, coxofemoral, and tarsal joints in dogs. Compend Contin Educ Vet. 2008 Dec;30(12):648-53.
- VON PFEIL DJ, DÉJARDIN LM, DECAMP CE, MEYER EG, LANSDOWNE JL, WEERTS RJ, HAUT RC. In vitro biomechanical comparison of a plate-rod combination-construct and an interlocking nail-construct for experimentally induced gap fractures in canine tibiae. Am J Vet Res. 2005 Sep;66(9):1536-43.
- ZAHN K, FREI R, WUNDERLE D, LINKE B, SCHWIEGER K, GUERGUIEV B, POHLER O, MATIS U. Mechanical properties of 18 different AO bone plates and the clamp-rod internal fixation system tested on a gap model construct. Vet Comp Orthop Traumatol. 2008;21(3):185-94.